RSSAll Entries in the "Fire Protection Engineering" Category

NIST Wind Driven Fire Simulation Video

NIST Wind Driven Fire Simulation Video

NIST Wind Driven Fire Simulation Video Wind Driven Fires Smoke and heat spreading through the corridors and the stairs of a building during a fire can limit building occupants’ ability to escape and can limit fire fighters’ ability to rescue them.  Changes in the building’s ventilation or presence of an external wind can increase the […]

Townhouse Flashover (VA)

Townhouse Flashover (VA)

An adult female suffered life-threatening injuries and 3 firefighters were transported with minor injuries as a result of a 2-alarm fire at a townhouse located on the 6800 block of Clowser Court in Springfield, VA. A Fairfax County Fire official says it took aggressive action by 85 firefighters to contain the fire and prevent extension […]

NIST Wind Driven Fires Programs

NIST Wind Driven Fires Programs

Wind Driven Fires Wind blowing into the broken window of a room on fire can turn a “routine room and contents fire” into a floor-to-ceiling firestorm. Historically, this has led to a significant number of firefighter fatalities and injuries, particularly in high-rise buildings where the fire must be fought from the interior of the structure. […]

Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction Under the United States Department of Homeland Security (DHS) Assistance to Firefighter Grant Program, Underwriters Laboratories examined fire service ventilation practices as well as the impact of changes in modern house […]

Wind Driven Fires

Wind Driven Fires

  A million dollar Baltimore County, Maryland  home was destroyed Sunday December 13, 2009  by a fire that tore through the 4,700-square-foot structure with such intensity that firefighters were forced to battle the flames from the exterior. Shortly after 21:00 hours, Baltimore County Fire Dispatch alerted crews for Fire Box 50-2 at 12607 Nancy Lee Court […]

VES:Flashover, Bailout and Close-call

VES:Flashover, Bailout and Close-call

N.J. Firefighter bailout from Second-Story Window as a result of room fashover An Asbury Park (NJ) firefighter was seriously burned while fighting an apartment fire in the seaside community. 41-year-old firefighter Jason Fazio was in listed in critical condition at St. Barnabas Burn Center in Livingston following Monday’s afternoon fire. Officials indicated that Firefighter Fazio was […]

Emerging Dynamics in the Modern Fire Environment

Emerging Dynamics in the Modern Fire Environment

[email protected] Podcasts and Internet Broadcasts for Fire and Emergency Service Professionals: Real Issues. Real Answers. Real Firefighters. Training & Tactics Talk Training & Tactics Talk: Emerging Dynamics in the Modern Fire Environment Joining Training and Tactics Talk host Douglas Cline as he talks with his guests from across the United States about the emerging dynamics […]

Tactical Patience and the New Considerations of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

Tactical Patience and the New Considerations of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction For many of you that have been following my writings and perspectives on building construction, firefighting, command risk management and operational excellence for firefighter safety have long recognized that I have been promoting and advocating the fact the fireground is changining, our stratgies […]

NIST Study on Charleston Furniture Store Fire Calls for National Safety Improvements

NIST Study on Charleston Furniture Store Fire Calls for National Safety Improvements

Major factors contributing to a rapid spread of fire at the Sofa Super Store in Charleston, S.C., on June 18, 2007, included large open spaces with furniture providing high fuel loads, the inward rush of air following the breaking of windows and a lack of sprinklers, according to a draft report released for public comment […]

FIREFIGHTER EXPOSURE TO SMOKE PARTICULATES

FIREFIGHTER EXPOSURE TO SMOKE PARTICULATES

Firefighter Exposure to Smoke Particulates Under a U.S. Department of Homeland Security (DHS) Assistance to Firefighter Grant, Underwriters Laboratories in collaboration with the Chicago Fire Department and the University of Cincinnati College of Medicine, recently completed a sixteen month study on the smoke and gas exposure firefighters confront during firefighting operations and subsequent contact exposure […]

Fire Service Features of Buildings and Fire Protection Systems

Fire Service Features of Buildings and Fire Protection Systems

Fire Service Features of Buildings and Fire Protection Systems Fire Service Features of Buildings and Fire Protection Systems Fire Service Features of Buildings and Fire Protection Systems is a very useful manual that was developed and published by the Occupational Safety and Health Administration, U.S. Department of Labor for the purpose to increase the safety […]

Fire Modeling Information at NIST

Fire Modeling Information at NIST

Fire Modeling Information at NIST (the links below are a compilation of programs and projects, news/events, and other pages tagged with this term) Building Occupant Evacuation (12/21/2010) Characterization of Internal Flow of Firefighter Respirator Project (10/05/2010) Cigarette Ignition Metrology Project (10/05/2010) Computer Based Fire Fighter Trainer Project (10/05/2010) Fires in the Wildland-Urban Interface – Development […]

NIST Predictive Model Development Project

NIST Predictive Model Development Project

(Top) Smokeview rendering of a fire in a cable spreading room of a nuclear power plant. (Bottom) Cable burning experiment conducted in the NIST Large Fire Laboratory and sponsored by the U.S. Nuclear Regulatory Commission. Predictive Model Development Project    Summary: Practicing engineers need tools to predict the fire performance of engineered buildings, their fire […]

Remembering Brackenridge 1991 Floor Collapse and LODD

Remembering Brackenridge 1991 Floor Collapse and LODD

Remembering Brackenridge, Pennsylvania December 20, 1991: Four Firefighters Killed, Trapped by Floor Collapse Four volunteer firefighters died when they were trapped by a partial floor collapse during a structure fire in Brackenridge, Pennsylvania, on the morning of December 20, 1991. All four were members of a mutual aid truck company that had responded to the […]

Tactical Patience and the New Considerations of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

Tactical Patience and the New Considerations of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction

    Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction  For many of you that have been following my writings and perspectives on building construction, firefighting, command risk management and operational excellence for firefighter safety have long recognized that I have been promoting and advocating the fact the fireground is changining, […]